- | ====== Review: Managed Low-Power Ethernet Switches ====== | ||
- | |||
- | In a past Mission-Log, | ||
- | |||
- | Luckily this situation has changed and we could test and already deploy a new pair of managed but very low power and fanless (silent) switches: The [[http:// | ||
- | |||
- | ====== ====== | ||
- | |||
- | ===== Power Consumption Analysis ===== | ||
- | |||
- | For better comparison all measurement results have been put together: | ||
- | |||
- | | || DGS-1008D G2 || DGS-1008D G3 || DGS-1100-8 Rev A1 || | ||
- | | || {{: | ||
- | | Clients |Mode|Current|Power|Current|Power|Current |Power| Wall | | ||
- | | 0 | Switch only | 66-93mA | 0.33-0.46W | 67-111mA | 0.33-0.55W | 105mA | | 0.8W | | ||
- | | 1 | Client Stdby | 100-160mA | 0.5-0.8W | 109-124mA | 0.54-0.62W | 131mA | | 1W | | ||
- | | 2 | Client Stdby | 141-194mA | 0.70-0.97W | 153-161mA | 0.76-0.80W | 154mA | | 1.1W | | ||
- | | 2 | Client Idle | 160-200mA | 0.8-1W | 170mA | 0.85W | 212mA | | 1.5W | | ||
- | | 3 | Client SCP | 250mA | 1.25W | 210-220mA | 1.07W | 238mA | | 1.7W | | ||
- | | 4 | Client SCP | 250mA | 1.25W | 210-220mA | 1.07W | 264mA | | 1.9W | | ||
- | |||
- | |||
- | ===== Reliability & Performance ===== | ||
- | |||
- | The DGS-1008D test candidate has been up and running 24x7 for more than 365 days now without any glitch or the necessity to power cycle. Power saving often leads to compromises in performance but the switch performed equally well compared to a CISCO 3560, that was in use before power consumption became a major issue. | ||
- | |||
- | ===== Conclusion ===== | ||
- | |||
- | Grid powered devices still have the luxury to be able to consume more power than absolutely necessary, since the limiting factor is money and not power itself. Off-Grid scenarios change that point of view on costs, as the value is no longer money, but the painfully finite element of power itself. | ||
- | |||
- | There are still a lot of devices out there with a standby-consumption of well above 10W, the DGS-1008D G3 connects 4 clients, actively transfers a lot of data and consumes about 1W. D-link obviously did a good job with this, although there is a little curiosity in StandBy: The G2 consumes a little less power in StandBy, when no clients are connected but the G3 saves considerably more power when active so overall the G3 is a very good evolutionary step in low-power consumption Gigabit-Ethernet technology. | ||
- | |||
- | The only drawback of these switches is their un-managed nature. Hopefully, in the future even managed switches can operate with this kind of power consumption profile. | ||
- | |||
- | Other manufacturers, | ||