This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
playground:mission-log-template1 [2015/06/18 09:07] – [Power Consumption Analysis] chrono | playground:mission-log-template1 [2015/07/07 12:01] – [Test-Setup] chrono | ||
---|---|---|---|
Line 1: | Line 1: | ||
- | ====== Review: Managed Low-Power | + | ====== Review: Managed Low-Power |
- | In a past Mission-Log, | + | In a past Mission-Log, |
+ | |||
+ | Luckily this situation | ||
====== ====== | ====== ====== | ||
Line 7: | Line 9: | ||
===== Power Consumption Analysis ===== | ===== Power Consumption Analysis ===== | ||
- | For better comparison all measurement results have been put together: | + | For better comparison all measurement results have been put together. A couple of people have been a bit unhappy, that we've only documented power consumption on the DC side in the past review (which is all we care about for off-grid usage). As a result, this time we've documented DC and Wall-Power consumption (with the original D-Link AC/DC plug). |
- | | || DGS-1008D G2 || DGS-1008D G3 || DGS-1100-8 Rev A1 || | + | ==== Test-Setup ==== |
- | | || {{: | + | |
- | | Clients |Mode|Current|Power|Current|Power|Current |Power| | + | Wall-Power was measured using [[http:// |
- | | 0 | Switch only | 66-93mA | 0.33-0.46W | 67-111mA | 0.33-0.55W | 105mA | | 0.8W | | + | |
- | | 1 | Client Stdby | 100-160mA | 0.5-0.8W | 109-124mA | 0.54-0.62W | 131mA | | 1W | | + | |
- | | 2 | Client Stdby | 141-194mA | 0.70-0.97W | 153-161mA | 0.76-0.80W | 154mA | | 1.1W | | + | ==== Results ==== |
- | | 2 | Client Idle | 160-200mA | 0.8-1W | 170mA | 0.85W | 212mA | | 1.5W | | + | |
- | | 3 | Client SCP | 250mA | 1.25W | 210-220mA | 1.07W | 238mA | | 1.7W | | + | | || DGS-1008D G2 || DGS-1008D G3 || DGS-1100-8 Rev A1 ||| |
- | | 4 | Client SCP | 250mA | 1.25W | 210-220mA | 1.07W | 264mA | | 1.9W | | + | | || {{: |
+ | | Clients |Mode| | ||
+ | | 0 | Switch only | 66-93mA | 0.33-0.46W | 67-111mA | 0.33-0.55W | 105mA | 0.52W | 0.8W | | ||
+ | | 1 | Client Stdby | 100-160mA | 0.5-0.8W | 109-124mA | 0.54-0.62W | 131mA | 0.65W | 1W | | ||
+ | | 2 | Client Stdby | 141-194mA | 0.70-0.97W | 153-161mA | 0.76-0.80W | 154mA | 0.77W | 1.1W | | ||
+ | | 2 | Client Idle | 160-200mA | 0.8-1W | 170mA | 0.85W | 212mA | 1.06W | 1.5W | | ||
+ | | 3 | Client SCP | 250mA | 1.25W | 210-220mA | 1.07W | 238mA | 1.2W | 1.7W | | ||
+ | | 4 | Client SCP | 250mA | 1.25W | 210-220mA | 1.07W | 264mA | 1.32W | 1.9W | | ||
===== Reliability & Performance ===== | ===== Reliability & Performance ===== | ||
- | The DGS-1008D test candidate has been up and running 24x7 for more than 365 days now without any glitch or the necessity to power cycle. | + | The DGS-1100-8 |
+ | |||
+ | <WRAP round tip> | ||
+ | When you make changes | ||
+ | </ | ||
===== Conclusion ===== | ===== Conclusion ===== |