This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
playground:mission-log-template1 [2015/06/18 07:50] – chrono | playground:mission-log-template1 [2015/07/07 12:01] – [Test-Setup] chrono | ||
---|---|---|---|
Line 1: | Line 1: | ||
+ | ====== Review: Managed Low-Power Switch DGS-1100-8 ====== | ||
+ | In a past Mission-Log, | ||
- | ====== D-Link " | + | Luckily this situation |
- | + | ||
- | Labeling things with the term " | + | |
- | + | ||
- | The DGS-1008D employs intelligent power saving modes to actively reduce energy consumption. Unconnected ports or ports without | + | |
====== ====== | ====== ====== | ||
Line 11: | Line 9: | ||
===== Power Consumption Analysis ===== | ===== Power Consumption Analysis ===== | ||
- | Fortunately muCCC had the 2nd generation | + | For better comparison all measurement results have been put together. A couple |
+ | |||
+ | ==== Test-Setup ==== | ||
+ | |||
+ | Wall-Power was measured | ||
+ | |||
+ | |||
+ | ==== Results ==== | ||
+ | |||
+ | | || DGS-1008D G2 || DGS-1008D G3 || DGS-1100-8 Rev A1 ||| | ||
+ | | || {{:blog: | ||
+ | | Clients |Mode| 5V DC Current | 5V DC Power | 5V DC Current | 5V DC Power | 5V DC Current | 5V DC Power| 230V AC Power | | ||
+ | | 0 | Switch only | 66-93mA | 0.33-0.46W | 67-111mA | 0.33-0.55W | 105mA | 0.52W | 0.8W | | ||
+ | | 1 | Client Stdby | 100-160mA | 0.5-0.8W | 109-124mA | 0.54-0.62W | 131mA | 0.65W | 1W | | ||
+ | | 2 | Client Stdby | 141-194mA | 0.70-0.97W | 153-161mA | 0.76-0.80W | 154mA | 0.77W | 1.1W | | ||
+ | | 2 | Client Idle | 160-200mA | 0.8-1W | 170mA | 0.85W | 212mA | 1.06W | 1.5W | | ||
+ | | 3 | Client SCP | 250mA | 1.25W | 210-220mA | 1.07W | 238mA | 1.2W | 1.7W | | ||
+ | | 4 | Client SCP | 250mA | 1.25W | 210-220mA | 1.07W | 264mA | 1.32W | 1.9W | | ||
- | | || DGS-1008D G2 || DGS-1008D G3 || | ||
- | | || {{: | ||
- | |Connected|Mode|Current|Power|Current|Power| | ||
- | |0 Clients|Switch only|66-93mA|0.33-0.46W|67-111mA|0.33-0.55W| | ||
- | |1 Client|Client Stdby|100-160mA|0.5-0.8W|109-124mA|0.54-0.62W| | ||
- | |2 Clients|Client Stdby|141-194mA|0.70-0.97W|153-161mA|0.76-0.80W| | ||
- | |2 Clients|Client Idle|160-200mA|0.8-1W|170mA|0.85W| | ||
- | |3 Clients|Client SCP|250mA|1.25W|210-220mA|1.07W| | ||
- | |4 Clients|Client SCP|250mA|1.25W|210-220mA|1.07W| | ||
===== Reliability & Performance ===== | ===== Reliability & Performance ===== | ||
- | The DGS-1008D test candidate has been up and running 24x7 for more than 365 days now without any glitch or the necessity to power cycle. | + | The DGS-1100-8 |
+ | |||
+ | <WRAP round tip> | ||
+ | When you make changes | ||
+ | </ | ||
===== Conclusion ===== | ===== Conclusion ===== |