lab:pigi:hardware [2013/07/30 17:57] – [Inductive Kickback Switch Mode Power Supply] Typo Fix chronolab:pigi:hardware [2023/04/19 13:56] (current) – [High Voltage] chrono
Line 72: Line 72:
 | < 100 V1.1 | EUR 4,97 | EUR 9,70 | Hand (EUR 0) |  20%  | TBD | | < 100 V1.1 | EUR 4,97 | EUR 9,70 | Hand (EUR 0) |  20%  | TBD |
 | >= 100 V1.1 | EUR 2,79 | EUR 7,05 | Outsourcing (TBD) |  15%   | TBD | | >= 100 V1.1 | EUR 2,79 | EUR 7,05 | Outsourcing (TBD) |  15%   | TBD |
-| >= 1000 V1.1 | EUR 0,70 | EUR 3,95 | Outsourcing (TBD) |  10%  | TBD  |+| >= 1000 V1.1 | EUR 0,70 | EUR 3,95 | Outsourcing (TBD) |  10%  | TBD | 
 + 
 +As we can see, it scales very well with numbers and a non-profit oriented production run could bring many modules to people for less than 20 EUR. If it were sold for more than 25 EUR (fully assembled), someone would really be ripping people off.
 ===== Assembly Instructions ===== ===== Assembly Instructions =====
  
Line 135: Line 137:
 | 10M (Fluke-87V internal resistor) | 230V | 230V | | 10M (Fluke-87V internal resistor) | 230V | 230V |
 | 10M + 42.3M (9x 4.7MOhm in series) | 63.7V | 333V | | 10M + 42.3M (9x 4.7MOhm in series) | 63.7V | 333V |
-| 10M + 1G ([[http://www.highvoltageshop.com/shop/article_RES_20kV_1G/Hochspannungswiderstand-20kV-1-GigaOhm-Messwiderstand%2C-Entladewiderstand.html|20kV 1 GigaOhm single resistor]]) | 4.56V | 460V |+| 10M + 1G ([[http://highvoltageshop.com/epages/b73088c0-9f9a-4230-9ffc-4fd5c619abc4.sf/de_DE/?ObjectPath=/Shops/b73088c0-9f9a-4230-9ffc-4fd5c619abc4/Products/RES_20kV_1G|20kV 1 GigaOhm single resistor]]) | 4.56V | 460V |
  
 Measured at: [+] Cathode of D1 (pin facing towards R2) [-] Cathode of GM Tube (HV- Pad) Measured at: [+] Cathode of D1 (pin facing towards R2) [-] Cathode of GM Tube (HV- Pad)
Line 143: Line 145:
 **Formula** **Formula**
  
-<x>+<m>
 V_actual = V_read * {{ R_meter + R_probe } / R_meter} V_actual = V_read * {{ R_meter + R_probe } / R_meter}
-</x>+</m>
  
 **Examples** **Examples**
  
-<x>+<m>
 63.7V * {{10 MOhm + 42.3 MOhm} / {10 MOhm}} \approx 333V  63.7V * {{10 MOhm + 42.3 MOhm} / {10 MOhm}} \approx 333V 
-</x>+</m>
  
-<x>+<m>
 4.56V * {{10 MOhm + 1000 MOhm} / {10 MOhm}} \approx 460V  4.56V * {{10 MOhm + 1000 MOhm} / {10 MOhm}} \approx 460V 
-</x>+</m>
  
  
Line 190: Line 192:
 ===== Radioactive Test Sources ===== ===== Radioactive Test Sources =====
  
-Since everything is regulated these days up to the point that only multi-national-companies can obtain the stuff they need to develop something it's quite a challenge to find sources to test your Geiger Counter with more than just the local dose rate. +Since everything is over-regulated these daysup to the point where only multi-national-corporations can obtain the resources needed to develop something easily, it's quite a challenge to find radioactive test sources to probe a Geiger Counter with more than just the local dose rate. So instead of having simple access to quality test-radiators which can be handled and stored in a safe manner, we have to improvise and hack something out of whatever we can find. When we consider that the regulation's original intent has to protect of people from harm, it backfired pretty well
  
 The mightyohm blog has compiled a list of things you can try to use:  The mightyohm blog has compiled a list of things you can try to use: